PRODUCT

PRODUCT

SMALL SEMICONDUCTOR HEATER
  • SMALL SEMICONDUCTOR HEATER
SMALL SEMICONDUCTOR HEATER

HGK 047 | 10W TO 30W

Applies to: The heaters are used in enclosures where condensation is to be prevented or the temperature may not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured. The heaters are designed for permanent operation.

download
  • > Dynamic heating up                                      > Wide voltage range

  • > Energy saving                                               > Clip fixing

The heaters are used in enclosures where condensation is to be prevented or the temperature may not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured. The heaters are designed for permanent operation.

TECHNICAL DRAWING


Small Semiconductor Heater HGK 047




Art. No.Operating voltageHeating capacity¹Inrush current max.Recommended
pre-fuse T (time delay)
Length (L)Weight (approx.)ConnectionApprovals
04700.0-00120-240V AC/DC²10W1.0A2.0A52mm0.1kg3 x 0,5mm² x 300mm cable (silicone)VDEEAC
04701.0-00120-240V AC/DC²20W2.5A4.0A60mm0.2kg3 x 0,5mm² x 300mm cable (silicone)VDEEAC
04702.0-00120-240V AC/DC²30W3.0A4.0A70mm0.2kg3 x 0,5mm² x 300mm cable (silicone)VDEEAC
04700.9-00120-230V AC/DC10W1.0A2.0A52mm0.1kg3 x AWG 20 x 300mm cableUL File No. E150057EAC
04701.9-00120-230V AC/DC20W1.5A2.0A70mm0.2kg3 x AWG 20 x 300mm cableUL File No. E150057EAC
04702.9-00120-230V AC/DC30W1.5A2.0A100mm0.2kg3 x AWG 20 x 300mm cableUL File No. E150057EAC


TECHNICAL DATA


Heating elementPTC resistor - temperature limiting
Heater bodyextruded aluminium profile, anodised
Mountingclip for 35mm DIN rail, EN 60715
Fitting positionvertical airflow (air outlet up, connection on bottom)
Operating/Storage temperature-45 to +70°C (-49 to +158°F)
Operating/Storage humiditymax. 90% RH (non-condensing)
Protection type/Protection classIP44 / I (earthed)
Accessoiresscrew fixing, Art. No. 09024.0-00 (1 packing unit = 2 pieces)
Noteother voltages on request


¹ at +20°C (+68°F) ambient temperature; ² (min. 110V, max 265V) Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%.