PRODUCT

PRODUCT

HAZARDOUS AREA HEATER
  • HAZARDOUS AREA HEATER
HAZARDOUS AREA HEATER

CREX 020 | 50 W, 100 W (T5)

Applies to: Compact convection heater of temperature class T5 (100 °C max.) for the prevention of formation of condensation, temperature fluctuations, and for protection against frost within control and switch cabinets, as well as measuring equipment located in areas with explosion hazard, underground mines or mines susceptible to firedamp.

download
  • > For areas with explosion and firedamp hazard

  • Large convection surface

  • Clip and screw flange fixing

  • Ready-to-use with strain relief

  • Maintenance free

  • Temperature Class T5

Compact convection heater of temperature class T5 (100 °C max.) for the prevention of formation of condensation, temperature fluctuations, and for protection against frost within control and switch cabinets, as well as measuring equipment located in areas with explosion hazard, underground mines or mines susceptible to firedamp.

TECHNICAL DRAWING


CREx 020 with clip fixing


CREX 020 with screw flange fixing


Art. No.
Clip fixing
Cable 1 m    |    Cable 2 m

Art. No.
Screw flange fixing
Cable 1 m    |    Cable 2 m    |    Hole spacing X

Operating
voltage

Heating
capacity

Rec. pre-fuse T
(time-delayed)

Dimensions
(D x W x H)

Weight
(approx.)

02051.0-00

02051.0-02

02051.0-10

02051.0-12

225 mm

AC 230 V

50 W

0.5 A

120 x 60 x 180 mm

1.4 kg

02051.9-00

02051.9-02

02051.9-10

02051.9-12

225 mm

AC 120 V

50 W

1.0 A

120 x 60 x 180 mm

1.4 kg

    -


02052.0-12

02052.0-12

350 mm

AC 230 V

100 W

1.0 A

160 x 80 x 300 mm

2.8 kg

    -


02052.9-12

02052.9-12

350 mm

AC 120 V

100 W

2.0 A

160 x 80 x 300 mm

2.8 kg


TECHNICAL DATA


Temperature classT5
Ex Protection type EX II 2 GD
Gases
Dusts
Mine applications

Ex db IIC T5 Gb
Ex tb IIIC T100°C Db IP66
I M2 Ex db I Mb
Ambient temperature-60 to +50 °C (-76 to +122 °F)
Surface temperaturemax. +100 °C (+212 °F)
Heating elementhigh performance cartridge
Heater bodyaluminium profile, silver anodised
Connectionsilicone cable (halogen-free) 3 x 0.75 mm²
Connection PE0.75 to 2.5 mm²
Mountingclip for 35 mm DIN rail, EN 60715
for heating body size 120 x 60 mm;
screw fixing with 2 plug-on flanges for all heating body sizes,
optional widthwise mounting
Fitting positionvertical airflow (connection on bottom)
Storage temperature-60 to +85 °C (-76 to +185 °F)
Operating/Storage humiditymax. 90% RH (non-condensing)
Protection type/Protection classIP66 / I (earthed)
Approvals

EPS 16 ATEX 1 109 X
IECEx EPS 16.0048X
IN METRO DNV 18.0010 X
EAC ТС RU С-FR.ГБ08.В.02639